Ramo Auditorium Lighting

On this page:
Control •
Circuits •
Lighting Positions •
Color •
Standard House Plot •
Lighting Instruments
Control
An ETC ION (with 2x20 Fader Wing) is located in the Booth at the rear of the Auditorium. This controls 96 ETC 2.4k Sensor Dimmers. Dimmer Per Circuit.

Ion Software Features
- Available in 1024, 1536 and 2048 output configurations
- Dedicated master playback fader pair
- Dedicated grand master and blackout switch
- 999 cue lists
- 200 active playbacks
- 300 submasters
- 4 x 1000 palettes (Intensity, Focus, Color, Beam)
- 1000 presets, effects and macros
- 4 pageable encoders
- Channel summary or table views, user configurable in live/blind
- Blind spreadsheet views
- Offline programming on PC (Vista or XP) and native on Macintosh (OS X Power PC or Intel)
- Data import from ETC Obsession, Express/ion, Emphasis and Strand Show files via ASCII
- Show file compatibility with Eos
- Client/server networking and synchronized backup
Product Features
- Supports up to two high-resolution DVI monitors
- Integral LCD for softkeys and non-intensity parameter control
- 2 x DMX512 outputs, RDM ready
- ETCNet2 and Net3 native
- Hard disk memory and USB compatible external storage
- MIDI In/Out (additional time code functions via external gateways)
- Contact Closure Triggers
- 5 multipurpose USB bus (pointing devices,printer, mouse, keyboard, touchscreens, flash drives)
- Audio In/Out
- Phone remote control
Curtain and screen controls are located both in the booth and at the stage manager's console backstage.
Auditorium house lights can be controlled from both the lighting console and the stage manager's console.
Circuits
Stage lighting circuits are 20-amp, 115 volt.
Stage connectors are twist-lock. Adaptors are available for converting from twist lock to stage pin or edison connectors.
Lighting Positions
In addition to the two front-of-house positions (see diagram below), there are eight pipes on stage which can be used for lighting. (see cross section)
Two hanging light ladders are available for side lighting. Six instruments can be hung on each ladder unit.
There are no box boom positions.
Catwalks provide easy access to the two front-of-house positions.
A portable Tallescope ladder is available for hanging and focusing instruments on stage
Color
An ample supply of all Roscolene and Roscolux colors is stocked.
Standard House Plot
PDF (1/4 scale; prints on 11x17 paper)
Lighting Instruments
Type | Wattage | Quantity | Position |
---|---|---|---|
40º ETC Source 4 | 750 | 22 | Movable |
50º ETC Source 4 | 750 | 8 | Movable |
6" Strand Fresnel | 1000 | 10 | Movable |
3-Color Century Strip | 150 | 6 | Movable |
instance | Type | Wattage | Focus |
---|---|---|---|
Second Beam | |||
1 | 40º ETC Source 4 | 750 | Lectern |
2 | 40º ETC Source 4 | 750 | Area 3B Front |
3 | 40º ETC Source 4 | 750 | Area 3B Front |
4 | 40º ETC Source 4 | 750 | Area 3B Front |
5 | 40º ETC Source 4 | 750 | Area 3B Front |
6 | 40º ETC Source 4 | 750 | Area 3B Front |
7 | 40º ETC Source 4 | 750 | Area 3B Front |
8 | 40º ETC Source 4 | 750 | Area 3B Front |
9 | 40º ETC Source 4 | 750 | Area 3B Front |
10 | 40º ETC Source 4 | 750 | Area 3B Front |
11 | 40º ETC Source 4 | 750 | Area 3B Front |
12 | 40º ETC Source 4 | 750 | Area 3B Front |
13 | 40º ETC Source 4 | 750 | Area 3B Front |
14 | 40º ETC Source 4 | 750 | Area 3B Front |
15 | 40º ETC Source 4 | 750 | Area 3B Front |
16 | 40º ETC Source 4 | 750 | Area 3B Front |
17 | 40º ETC Source 4 | 750 | Area 3B Front |
18 | 40º ETC Source 4 | 750 | Area 3B Front |
19 | 40º ETC Source 4 | 750 | Area 3B Front |
20 | 40º ETC Source 4 | 750 | Area 3B Front |
21 | 40º ETC Source 4 | 750 | Area 3B Front |
First Beam | |||
22 | 40º ETC Source 4 | 750 | Lectren |
24 | 40º ETC Source 4 | 750 | Special |
25B | 50º ETC Source 4 | 750 | Area 3B Down |
25A | 50º ETC Source 4 | 750 | Area 3A Down |
26 | 40º ETC Source 4 | 750 | Special |
27 | 50º ETC Source 4 | 750 | Special |
28 | 40º ETC Source 4 | 750 | Special |
29B | 50º ETC Source 4 | 750 | Area 2B Down |
29A | 50º ETC Source 4 | 750 | Area 2A Down |
31B | 50º ETC Source 4 | 750 | Special |
31A | 50º ETC Source 4 | 750 | Special |
33B | 50º ETC Source 4 | 750 | Area 2B Down |
33A | 50º ETC Source 4 | 750 | Area 2A Down |
34 | 40º ETC Source 4 | 750 | Special |
35 | 50º ETC Source 4 | 750 | Special |
36 | 40º ETC Source 4 | 750 | Special |
38B | 50º ETC Source 4 | 750 | Area 1B Down |
38A | 50º ETC Source 4 | 750 | Area 1B Down |
39 | 40º ETC Source 4 | 750 | Lectern |
40 | 40º ETC Source 4 | 750 | Special |
First Electric | |||
53 | 6" Strand Fresnel | 1000 | Area 6 Down |
54 | 6" Strand Fresnel | 1000 | Area 7 Down |
55 | 6" Strand Fresnel | 1000 | Area 8 Down |
66 | 6" Strand Fresnel | 1000 | Area 6 Down |
67 | 6" Strand Fresnel | 1000 | Area 7 Down |
68 | 6" Strand Fresnel | 1000 | Area 8 Down |
Second Electric | |||
41 | 6X9 Strand Leko | 750 | Curtain Toning |
65 | 6X9 Strand Leko | 750 | Curtain Toning |
Third Electric | |||
57 | 6" Fres | 1000 | SR Backlight |
60 | 6" Fres | 1000 | SR Backlight |
61 | 6" Fres | 1000 | SR Backlight |
63 | 6" Fres | 1000 | SR Backlight |
Fourth Electric | |||
50 | 3-color Century Strip | 150 | CYC |
51 | 3-color Century Strip | 150 | CYC |
52 | 3-color Century Strip | 150 | CYC |